Important
Many cars start a countdown to a start block with this fault. Have it checked in good time.
What does it mean?
The SCR catalytic converter uses AdBlue to break down nitrogen oxides. A NOx sensor after the converter measures the result. The control unit sees that too much NOx gets through. Bank 1 is the side of the engine with cylinder 1. An in-line engine only has bank 1.
This is the general meaning of the code. Manufacturers sometimes use a code in their own way, so your garage may give a more specific explanation for your car.
What you may notice
- Engine warning light or AdBlue warning
- Countdown on the display
- Usually no difference in driving
Common causes
- Poor AdBlue quality or wrong fluid
- Dosing valve that sprays too little or is crystallised
- Defective NOx sensor
- Aged or contaminated SCR catalytic converter
What you can check yourself
- Make sure you use fresh AdBlue (ISO 22241) from a sealed container
- Write down any countdown on the display
What to ask the garage
- Was the AdBlue quality tested?
- Is the dosing valve spraying properly?
- Are both NOx sensors giving plausible values?
Checked on 14 November 2026